Ionization chamber dosimetry based on 60Co absorbed dose to water calibration for diagnostic kilovoltage x-ray beams.

Takeshi Ohno, Fujio Araki, Suzuna Umeno
The purpose of this study was to develop a new ionization chamber dosimetry formalism for diagnostic kilovoltage x-ray beams based on a 60Co absorbed dose-to-water calibration coefficient . To validate the new chamber dosimetry, 39 fluence spectra of kilovoltage x-rays were calculated, using a SpekCalc program, for Al half-value-layer (Al-HVL) values of 1.4 8.5 mm and tube voltages of 50 137.6 kVp. We used these spectra to calculate the beam quality conversion factor for kilovoltage x-ray beams Qx to a 60Co beam for a PTW 30013 Farmer ionization chamber in a reference geometrical setup (depth = 1 cm in water, field size = 20 × 20 cm2). The absorbed dose to water for kilovoltage x-rays was obtained using and . Meanwhile, the water surface dose based on the air kerma calibration coefficient NK was obtained using a Monte Carlo-calculated correction factor CF (corresponding to in AAPM TG-61) for the 39 x-ray fluence spectra. The absorbed dose based on was validated by comparing the water surface dose for the 39 x-ray fluence spectra with the water surface dose based on NK. The water surface dose based on was obtained using Monte Carlo-calculated percentage depth doses. For Al-HVL ranging from 1.4 to 8.5 mm, ranged from 0.884 to 0.956 and CF ranged from 1.264 to 1.663. The water surface dose based on for the x-ray fluence spectra was 1.0% higher on average than that based on NK, except for Al-HVLs of 1.4 and 1.5 mm and 1% was within their uncertainty ranges. Therefore, it is possible to use the absorbed dose-to-water value based on instead of on NK. With the new chamber dosimetry, the chamber reading can be easily converted to the absorbed dose using and the calculated . .

Publisher URL: http://doi.org/10.1088/1361-6560/aad9c0

DOI: 10.1088/1361-6560/aad9c0

You might also like
Discover & Discuss Important Research

Keeping up-to-date with research can feel impossible, with papers being published faster than you'll ever be able to read them. That's where Researcher comes in: we're simplifying discovery and making important discussions happen. With over 19,000 sources, including peer-reviewed journals, preprints, blogs, universities, podcasts and Live events across 10 research areas, you'll never miss what's important to you. It's like social media, but better. Oh, and we should mention - it's free.

  • Download from Google Play
  • Download from App Store
  • Download from AppInChina

Researcher displays publicly available abstracts and doesn’t host any full article content. If the content is open access, we will direct clicks from the abstracts to the publisher website and display the PDF copy on our platform. Clicks to view the full text will be directed to the publisher website, where only users with subscriptions or access through their institution are able to view the full article.