Multiple Myeloma Cell Drug Responses Differ in Thermoplastic vs PDMS Microfluidic Devices

Multiple Myeloma Cell Drug Responses Differ in Thermoplastic vs PDMS Microfluidic Devices
Thomas A. Moore, Edmond W. K. Young, Peter Brodersen
Poly(dimethylsiloxane) (PDMS) is a commonly used elastomer for fabricating microfluidic devices, but it has previously been shown to absorb hydrophobic molecules. Although this has been demonstrated for molecules such as estrogen and Nile Red, the absorption of small hydrophobic molecules in PDMS specifically used to treat cancer and its subsequent impact on cytotoxicity measurements and assays have not been investigated. This is critical for the development of microfluidic chemosensitivity and resistance assay (CSRA) platforms that have shown potential to help guide clinical therapy selection and which rely on the accuracy of the readout involving interactions between patient-derived cells and cancer drugs. It is thus important to address the issue of drug absorption into device material. We investigated drug absorption into microfluidic devices by treating multiple myeloma (MM) tumor cells with two MM drugs (bortezomib (BTZ) and carfilzomib (CFZ)) in devices fabricated using three different materials (polystyrene (PS), cyclo-olefin polymer (COP), and PDMS). Half-maximal inhibitory concentrations (IC50) were obtained for each drug–material combination, and an increase in IC50 of ∼4.3× was observed in PDMS devices compared to both thermoplastic devices. Additionally, each MM drug was exposed to polymer samples, and samples were analyzed using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to characterize adsorption and absorption of the drugs into each material. ToF-SIMS data showed the bias observed in IC50 values found in PDMS devices was directly related to the absorption of drug during dose–response experiments. Specifically, BTZ and CFZ absorption in both PS and COP were all in the range of ∼100–300 nm, whereas BTZ and CFZ absorption in PDMS was ∼5.0 and ∼3.5 μm, respectively. These results highlight the biases that exist in PDMS devices and the importance of material selection in microfluidic device design, especially in applications involving drug cytotoxicity and hydrophobic molecules.

Publisher URL: http://dx.doi.org/10.1021/acs.analchem.7b02351

DOI: 10.1021/acs.analchem.7b02351

You might also like
Discover & Discuss Important Research

Keeping up-to-date with research can feel impossible, with papers being published faster than you'll ever be able to read them. That's where Researcher comes in: we're simplifying discovery and making important discussions happen. With over 19,000 sources, including peer-reviewed journals, preprints, blogs, universities, podcasts and Live events across 10 research areas, you'll never miss what's important to you. It's like social media, but better. Oh, and we should mention - it's free.

  • Download from Google Play
  • Download from App Store
  • Download from AppInChina

Researcher displays publicly available abstracts and doesn’t host any full article content. If the content is open access, we will direct clicks from the abstracts to the publisher website and display the PDF copy on our platform. Clicks to view the full text will be directed to the publisher website, where only users with subscriptions or access through their institution are able to view the full article.