4 years ago

Predicting Fluid Responsiveness in Critically Ill Patients by Using Combined End-Expiratory and End-Inspiratory Occlusions With Echocardiography

Predicting Fluid Responsiveness in Critically Ill Patients by Using Combined End-Expiratory and End-Inspiratory Occlusions With Echocardiography
Jozwiak, Mathieu, Depret, François, Teboul, Jean-Louis, Monnet, Xavier, Lai, Christopher, Alphonsine, Jean-Emmanuel, Richard, Christian
Objectives: Objectives:First, we aimed at assessing whether fluid responsiveness is predicted by the effects of an end-expiratory occlusion on the velocity-time integral of the left ventricular outflow tract. Second, we investigated whether adding the effects of an end-inspiratory occlusion and of an end-expiratory occlusion on velocity-time integral can predict fluid responsiveness with similar reliability than end-expiratory occlusion alone but with a higher threshold, which might be more compatible with the precision of echocardiography. Design: Design:Diagnostic study. Setting: Setting:Medical ICU. Patients: Patients:Thirty mechanically ventilated patients in whom fluid administration was planned. Interventions: Interventions:A 15-second end-expiratory occlusion and end-inspiratory occlusion, separated by 1 minute, followed by a 500-mL saline administration. Measurements and Main Results: Measurements and Main Results:Pulse contour analysis–derived cardiac index and velocity-time integral were measured during the last 5 seconds of 15-second end-inspiratory occlusion and end-expiratory occlusion and after fluid administration. End-expiratory occlusion increased velocity-time integral more in responders than in nonresponders to fluid administration (11% ± 5% vs 3% ± 1%, respectively; p < 0.0001), and end-inspiratory occlusion decreased velocity-time integral more in responders than in nonresponders (12% ± 5% vs 5% ± 2%, respectively; p = 0.0002). When adding the absolute values of changes in velocity-time integral observed during both occlusions, velocity-time integral changed by 23% ± 9% in responders and by 8% ± 3% in nonresponders. Fluid responsiveness was predicted by the end-expiratory occlusion–induced change in velocity-time integral with an area under the receiver operating characteristic curve of 0.938 (0.785–0.989) and a threshold value of 5%. Fluid responsiveness was predicted by the sum of absolute values of changes in velocity-time integral during both occlusions with a similar reliability (area under the receiver operating characteristic curve = 0.973 [0.838–1.000]) but with a threshold of 13%. Both sensitivity and specificity were 93% (68–100%). Conclusions: Conclusions:If consecutive end-inspiratory occlusion and end-expiratory occlusion change velocity-time integral is greater than or equal to 13% in total, fluid responsiveness is accurately predicted. This threshold is more compatible with the precision of echocardiography than that obtained by end-expiratory occlusion alone.
You might also like
Discover & Discuss Important Research

Keeping up-to-date with research can feel impossible, with papers being published faster than you'll ever be able to read them. That's where Researcher comes in: we're simplifying discovery and making important discussions happen. With over 19,000 sources, including peer-reviewed journals, preprints, blogs, universities, podcasts and Live events across 10 research areas, you'll never miss what's important to you. It's like social media, but better. Oh, and we should mention - it's free.

  • Download from Google Play
  • Download from App Store
  • Download from AppInChina

Researcher displays publicly available abstracts and doesn’t host any full article content. If the content is open access, we will direct clicks from the abstracts to the publisher website and display the PDF copy on our platform. Clicks to view the full text will be directed to the publisher website, where only users with subscriptions or access through their institution are able to view the full article.