5 years ago

Development of a validated LC- MS/MS method for the quantification of 19 endogenous asthma/COPD potential urinary biomarkers

Development of a validated LC- MS/MS method for the quantification of 19 endogenous asthma/COPD potential urinary biomarkers
Obstructive airways inflammatory diseases sometimes show overlapping symptoms that hinder their early and correct diagnosis. Current clinical tests are tedious and are of inadequate specificity in special population such as the elderly and children. Therefore, we are developing tandem mass spectrometric (MS/MS) methods for targeted analysis of urine biomarkers. Recently, proton-nuclear magnetic resonance (1H NMR) analysis proposed 50 urinary metabolites as potential diagnostic biomarkers among asthma and chronic obstructive pulmonary disease (COPD) patients. Metabolites are divided into 3 groups based on chemical nature. For group 1 (amines and phenols, 19 urinary metabolites), we developed and validated a high performance liquid chromatographic (HPLC)-MS/MS method using differential isotope labeling with dansyl chloride. Method development included the optimization of the derivatization reaction, the MS/MS conditions, and the chromatographic separation. Linearity varied from 2 to 4800 ng/mL and the use of 13C2-labeled derivatives allowed for the correction of matrix effects as well as the unambiguous confirmation of the identity of each metabolite in the presence of interfering isomers in urine. Despite the challenges associated with method validation, the method was fully validated as per the food and drug administration (FDA) and the European medicines agency (EMA) recommendations. Validation criteria included linearity, precision, accuracy, dilution integrity, selectivity, carryover, and stability. Challenges in selectivity experiments included the isotopic contributions of the analyte towards its internal standard (IS), that was addressed via the optimization of the IS concentration. In addition, incurred sample analysis was performed to ensure that results from patient samples are accurate and reliable. The method was robust and reproducible and is currently being applied in a cohort of asthma and COPD patient urine samples for biomarker discovery purposes.

Publisher URL: www.sciencedirect.com/science

DOI: S0003267017308966

You might also like
Discover & Discuss Important Research

Keeping up-to-date with research can feel impossible, with papers being published faster than you'll ever be able to read them. That's where Researcher comes in: we're simplifying discovery and making important discussions happen. With over 19,000 sources, including peer-reviewed journals, preprints, blogs, universities, podcasts and Live events across 10 research areas, you'll never miss what's important to you. It's like social media, but better. Oh, and we should mention - it's free.

  • Download from Google Play
  • Download from App Store
  • Download from AppInChina

Researcher displays publicly available abstracts and doesn’t host any full article content. If the content is open access, we will direct clicks from the abstracts to the publisher website and display the PDF copy on our platform. Clicks to view the full text will be directed to the publisher website, where only users with subscriptions or access through their institution are able to view the full article.