3 years ago

Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures

Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures
The aim of this study was to determine whether the association of small label size of the surgical valve with increased mortality after transcatheter valve-in-valve (ViV) implantation is, at least in part, related to pre-existing prosthesis-patient mismatch (PPM) (i.e., a bioprosthesis that is too small in relation to body size). Background Transcatheter ViV implantation is an alternative for the treatment of patients with degenerated bioprostheses. Small label size of the surgical valve has been associated with increased mortality after ViV implantation. Methods Data from 1,168 patients included in the VIVID (Valve-in-Valve International Data) registry were analyzed. Pre-existing PPM of the surgical valve was determined using a reference value of effective orifice area for each given model and size of implanted prosthetic valve indexed for body surface area. Severe PPM was defined according to the criteria proposed by the Valve Academic Research Consortium 2: indexed effective orifice area <0.65 cm2/m2 if body mass index is <30 kg/m2 and <0.6 cm2/m2 if BMI is ≥30 kg/m2. The primary study endpoint was 1-year mortality. Results Among the 1,168 patients included in the registry, 89 (7.6%) had pre-existing severe PPM. Patients with severe PPM had higher 30-day (10.3%, p = 0.01) and 1-year (unadjusted: 28.6%, p < 0.001; adjusted: 19.3%, p = 0.03) mortality rates compared with patients with no severe PPM (4.3%, 11.9%, and 10.9%, respectively). After adjusting for surgical valve label size, Society of Thoracic Surgeons score, renal failure, diabetes, and stentless surgical valves, presence of pre-existing severe PPM was associated with increased risk for 1-year mortality (odds ratio: 1.88; 95% confidence interval: 1.07 to 3.28; p = 0.03). Patients with severe PPM also more frequently harbored high post-procedural gradients (mean gradient ≥20 mm Hg). Conclusions Pre-existing PPM of the failed surgical valve is strongly and independently associated with increased risk for mortality following ViV implantation.

Publisher URL: www.sciencedirect.com/science

DOI: S1936879817318009

You might also like
Discover & Discuss Important Research

Keeping up-to-date with research can feel impossible, with papers being published faster than you'll ever be able to read them. That's where Researcher comes in: we're simplifying discovery and making important discussions happen. With over 19,000 sources, including peer-reviewed journals, preprints, blogs, universities, podcasts and Live events across 10 research areas, you'll never miss what's important to you. It's like social media, but better. Oh, and we should mention - it's free.

  • Download from Google Play
  • Download from App Store
  • Download from AppInChina

Researcher displays publicly available abstracts and doesn’t host any full article content. If the content is open access, we will direct clicks from the abstracts to the publisher website and display the PDF copy on our platform. Clicks to view the full text will be directed to the publisher website, where only users with subscriptions or access through their institution are able to view the full article.