5 years ago

Precisão e confiabilidade de um teste imuno-cromatográfico rápido NS1 para diagnóstico DENV-1 no ponto de atendimento e no laboratório

Maria Angelica Borges dos Santos, Raquel de Vasconcellos Carvalhaes de Oliveira, Verónica Elizabeth Mata, Cintia Damasceno dos Santos Rodrigues, Aline da Silva Santos, Yara Hahr Marques Hökerberg, Sonia Regina Lambert Passos, Anna Carolina Fontoura Seixas Rangel Maciel, Levy Vilas Boas Fukuoka, Guilherme Miguéis Berardinelli

Abstract

Background

Rapid immunochromatographic tests (ICT) for dengue non-structural protein 1 (NS1) have shown good performance for diagnosing acute-phase dengue in serum in laboratory settings, but rarely have been assessed in whole blood and at point of care (POC). This study compare the accuracy and inter- and intra-observer reliability of the NS1 Bioeasy™ ICT in whole blood at POC versus serum in the laboratory, during a DENV-1 epidemic.

Methods

Cross-sectional study involving 144 adults spontaneously demanding care in an emergency department within 4 days of onset of acute febrile illness. Accuracy of NS1 Bioeasy™ ICT was compared in whole blood and serum, both at 15 and 30 min, blinded to the reference RT-PCR or NS1 ELISA. Non-dengue patients were also tested for Zika virus with RT-PCR. Reliability of whole blood and serum readings by the same or different observers was measured by simple kappa (95% CI).

Results

At 15 min, sensitivity (Sn) of NS1 Bioeasy™ ICT in whole blood/POC was 76.7% (95% CI: 68.0–84.1) and specificity (Sp) was 87.0% (95% CI: 66.4–97.2). Sn in serum/laboratory was 82% (95% CI: 74.1–88.6) and Sp 100% (95% CI: 85.8–100). Positive likelihood ratio was 5.9 (95% CI: 2.0–17.0) for whole blood/POC and 19.8 (95% CI: 2.9–135.1) for serum/laboratory. Reliability of matched readings of whole blood/POC and serum/laboratory by the same observer (k = 0.83, 95% CI: 0.74–0.93) or different observers (k = 0.81, 95% CI: 0.72–0.92) was almost perfect, with higher discordant levels in the absence of dengue. Results did not differ statistically at 5%.

Conclusions

NS1 Bioeasy™ ICT in DENV-1 epidemics is a potentially confirmatory test. Invalid results at 15 min should be reread at 30 min. To optimize impact of implementing ICT in the management of false-negatives it should be incorporated into an algorithm according to setting and available specimen.

Trial registration

UTN U1111-1145-9451.

Publisher URL: https://link.springer.com/article/10.1186/s12879-017-2679-z

DOI: 10.1186/s12879-017-2679-z

You might also like
Discover & Discuss Important Research

Keeping up-to-date with research can feel impossible, with papers being published faster than you'll ever be able to read them. That's where Researcher comes in: we're simplifying discovery and making important discussions happen. With over 19,000 sources, including peer-reviewed journals, preprints, blogs, universities, podcasts and Live events across 10 research areas, you'll never miss what's important to you. It's like social media, but better. Oh, and we should mention - it's free.

  • Download from Google Play
  • Download from App Store
  • Download from AppInChina

Researcher displays publicly available abstracts and doesn’t host any full article content. If the content is open access, we will direct clicks from the abstracts to the publisher website and display the PDF copy on our platform. Clicks to view the full text will be directed to the publisher website, where only users with subscriptions or access through their institution are able to view the full article.