3 years ago

A novel approach using the enhanced-view totally extraperitoneal (eTEP) technique for laparoscopic retromuscular hernia repair

Adam S. Weltz, Adrian Park, Ramana Balasubramanian, Igor Belyansky, Udai S. Sibia, Victor Gheorghe Radu, Yuri Novitsky, H. Reza Zahiri, Jorge Daes

Abstract

Background

The enhanced-view totally extraperitoneal (eTEP) technique has been previously described for Laparoscopic Inguinal Hernia Repair. We present a novel application of the eTEP access technique for the repair of ventral and incisional hernias.

Methods

Retrospective review of consecutive laparoscopic retromuscular hernia repair cases utilizing the eTEP access approach from five hernia centers between August 2015 and October 2016 was conducted. Patient demographics, hernia characteristics, operative details, perioperative complications, and quality of life outcomes utilizing the Carolina’s Comfort Scale (CCS) were included in our data analysis.

Results

Seventy-nine patients with mean age of 54.9 years, mean BMI of 31.1 kg/m2, and median ASA of 2.0 were included in this analysis. Thirty-four percent of patients had a prior ventral or incisional hernia repair. Average mesh area of 634.4 cm2 was used for an average defect area of 132.1 cm2. Mean operative time, blood loss, and length of hospital stay were 218.9 min, 52.6 mL, and 1.8 days, respectively. There was one conversion to intraperitoneal mesh placement and one conversion to open retromuscular mesh placement. Postoperative complications consisted of seroma (n = 2) and trocar site dehiscence (n = 1). Comparison of mean pre- and postoperative CCS scores found significant improvements in pain (68%, p < 0.007) and movement limitations (87%, p < 0.004) at 6-month follow-up. There were no readmissions within 30 days and one hernia recurrence at mean follow-up of 332 ± 122 days.

Conclusions

Our initial multicenter evaluation of the eTEP access technique for ventral and incisional hernias has found the approach feasible and effective. This novel approach offers flexible port set-up optimal for laparoscopic closure of defects, along with wide mesh coverage in the retromuscular space with minimal transfascial fixation.

Publisher URL: https://link.springer.com/article/10.1007/s00464-017-5840-2

DOI: 10.1007/s00464-017-5840-2

You might also like
Never Miss Important Research

Researcher is an app designed by academics, for academics. Create a personalised feed in two minutes.
Choose from over 15,000 academics journals covering ten research areas then let Researcher deliver you papers tailored to your interests each day.

  • Download from Google Play
  • Download from App Store
  • Download from AppInChina

Researcher displays publicly available abstracts and doesn’t host any full article content. If the content is open access, we will direct clicks from the abstracts to the publisher website and display the PDF copy on our platform. Clicks to view the full text will be directed to the publisher website, where only users with subscriptions or access through their institution are able to view the full article.