5 years ago

Evaluation of the use of unipolar voltage amplitudes for detection of myocardial scar assessed by cardiac magnetic resonance imaging in heart failure patients

Daniel Suerder, Masih Mafi-Rad, Francesco Maffessanti, Kevin Vernooy, Rolf Krause, Sebastiaan C. A. M. Bekkers, Angelo Auricchio, Maria Luce Caputo, François Regoli, Giulio Conte, Stef Zeemering, Uyên Châu Nguyên, Frits W. Prinzen, Antonius M. W. van Stipdonk, Tiziano Moccetti

by Uyên Châu Nguyên, Francesco Maffessanti, Masih Mafi-Rad, Giulio Conte, Stef Zeemering, François Regoli, Maria Luce Caputo, Antonius M. W. van Stipdonk, Sebastiaan C. A. M. Bekkers, Daniel Suerder, Tiziano Moccetti, Rolf Krause, Frits W. Prinzen, Kevin Vernooy, Angelo Auricchio

Background

Validation of voltage-based scar delineation has been limited to small populations using mainly endocardial measurements. The aim of this study is to compare unipolar voltage amplitudes (UnipV) with scar on delayed enhancement cardiac magnetic resonance imaging (DE-CMR).

Methods

Heart failure patients who underwent DE-CMR and electro-anatomic mapping were included. Thirty-three endocardial mapped patients and 27 epicardial mapped patients were investigated. UnipV were computed peak-to-peak. Electrograms were matched with scar extent of the corresponding DE-CMR segment using a 16-segment/slice model. Non-scar was defined as 0% scar, while scar was defined as 1–100% scar extent.

Results

UnipVs were moderately lower in scar than in non-scar (endocardial 7.1 [4.6–10.6] vs. 10.3 [7.4–14.2] mV; epicardial 6.7 [3.6–10.5] vs. 7.8 [4.2–12.3] mV; both p<0.001). The correlation between UnipV and scar extent was moderate for endocardial (R = -0.33, p<0.001), and poor for epicardial measurements (R = -0.07, p<0.001). Endocardial UnipV predicted segments with >25%, >50% and >75% scar extent with AUCs of 0.72, 0.73 and 0.76, respectively, while epicardial UnipV were poor scar predictors, independent of scar burden (AUC = 0.47–0.56). UnipV in non-scar varied widely between patients (p<0.001) and were lower in scar compared to non-scar in only 9/22 (41%) endocardial mapped patients and 4/19 (21%) epicardial mapped patients with scar.

Conclusion

UnipV are slightly lower in scar compared to non-scar. However, significant UnipV differences between and within patients and large overlap between non-scar and scar limits the reliability of accurate scar assessment, especially in epicardial measurements and in segments with less than 75% scar extent.

Publisher URL: http://journals.plos.org/plosone/article

DOI: 10.1371/journal.pone.0180637

You might also like
Discover & Discuss Important Research

Keeping up-to-date with research can feel impossible, with papers being published faster than you'll ever be able to read them. That's where Researcher comes in: we're simplifying discovery and making important discussions happen. With over 19,000 sources, including peer-reviewed journals, preprints, blogs, universities, podcasts and Live events across 10 research areas, you'll never miss what's important to you. It's like social media, but better. Oh, and we should mention - it's free.

  • Download from Google Play
  • Download from App Store
  • Download from AppInChina

Researcher displays publicly available abstracts and doesn’t host any full article content. If the content is open access, we will direct clicks from the abstracts to the publisher website and display the PDF copy on our platform. Clicks to view the full text will be directed to the publisher website, where only users with subscriptions or access through their institution are able to view the full article.